Garmin G1000
®
Cockpit Reference Guide for the Quest KODIAK 100
190-00645-04 Rev. A
72
Annunciations & Alerts
Flight
InstrumentsEIS
Nav/Com/
XPDR/AudioGPS Nav
Flight
PlanningProcedures
Hazard
Avoidance
Additional
Features
Abnormal
OperationAnnun/AlertsAppendixIndex
GIA 63W MESSAGE ADVISORIES (CONT.)
Message Comments
GIA1 COOLING
– GIA1
temperature too low.
The GIA1 and/or GIA2 temperature is too low
to operate correctly. Allow units to warm up to
operating temperature.
GIA2 COOLING
– GIA2
temperature too low.
GIA1 COOLING
– GIA1 over
temperature.
The GIA1 and/or GIA2 temperature is too
high. If problem persists, the system should be
serviced.
GIA2 COOLING
– GIA2 over
temperature.
GIA1 SERVICE
– GIA1 needs
service. Return the unit for repair.
The GIA1 and/or GIA2 self-test has detected
a problem in the unit. The system should be
serviced.
GIA2 SERVICE
– GIA2 needs
service. Return the unit for repair.
HW MISMATCH
– GIA hardware
mismatch. GIA1 communication
halted.
A GIA mismatch has been detected, where only
one is SBAS capable.
HW MISMATCH
– GIA hardware
mismatch. GIA2 communication
halted.
MANIFEST
– GIA1 software
mismatch, communication halted.
The GIA1 and/or GIA 2 has incorrect software
installed. The system should be serviced.
MANIFEST
– GIA2 software
mismatch, communication halted.
COM1 TEMP
– COM1 over temp.
Reducing transmitter power.
The system has detected an over temperature
condition in COM1 and/or COM2. The
transmitter is operating at reduced power. If the
problem persists, the system should be serviced.
COM2 TEMP
– COM2 over temp.
Reducing transmitter power.
COM1 SERVICE
– COM1 needs
service. Return unit for repair.
The system has detected a failure in COM1 and/or
COM2. COM1 and/or COM2 may still be usable.
The system should be serviced when possible.
COM2 SERVICE
– COM2 needs
service. Return unit for repair.