Page 5-4 G1000 System Maintenance Manual - Hawker Beechcraft G58
Revision 3 190-01180-02
Ensure that LRU is reporting data on System
Status page (LRU is ‘ONLINE’). Check data
path wiring as needed.
Retry configuration file load or try using a
different card. Ensure that the MFD is not
touched during the loading process.
Ensure that LRU part number is compatible
with Card Loader. Refer to the General
Arrangement Drawing 005-00606-12 and to
Section 3.6 of this document.
Replace LRU.
Software File Mismatch Alert appears in lower
right corner of PFD when started in normal mode:
Ensure that proper software file part number
and version were loaded to LRU. Refer to the
General Arrangement Drawing 005-00606-12
and to Section 5.4.
Check and ensure that correct Card Loader
was used during load process. Refer to the
General Arrangement Drawing 005-00606-12.
Reload software to LRU.
5.4 GRT 10 / GRC 10 XM REMOTE CONTROL TROUBLESHOOTING
Problem Action
GRT 10 not found
Verify GRT 10 is receiving power.
Verify the RF pairing ID entered into GRC 10 is correct.
GRT 10 connection lost
Verify that the GRC 10 is in RF range of the GRT 10.
Verify GRT 10 wiring and power.
GDL 69A not found
Verify wiring between GDL 69A and GRT 10.
Verify GDL 69A is powered on.
GDL 69A connection is lost
Verify wiring between GDL 69A and GRT 10.
Verify GDL 69A is powered on.
GRC 10 will not power on.
Verify batteries are installed.
Install fresh batteries. See Section 7.3.
5.5 SYSTEM COMMUNICATION HIERARCHY
The following criteria must be satisfied to be able to perform the desired operation:
Desired Operation Criteria for Success
Load Software to MFD or PFD Displays
SW Loader Card must be inserted in top slot
for each display to be loaded.
CLR & ENT keys must be held during power
up of display.
Power on only one display at a time during
software loading.