G1000 System Maintenance Manual - Hawker Beechcraft G36 Page 6-7
190-01259-00 Rev. 5
6.8 GIA 63W Removal & Replacement
Removal:
1. Make sure all airplane electrical power is disconnected.
2. Remove the MFD.
3. Unlock the GIA 63W handle by loosening the Phillips screw on the handle.
4. Pull the handle upward to unlock the GIA 63W. Gently remove the unit from the rack.
5. Place protective caps on the GIA 63W electrical connectors and rack connectors.
6. Remove the unit from the airplane.
Reinstallation:
1. Remove the protective caps from the GIA 63W electrical connectors and rack
connectors. Visually inspect the electrical connectors to make sure there are no bent or
damaged pins. Repair any damage.
NOTE
A handle-lock mechanism is used to guide and lock the LRU into place.
The handle has a locking stud that engages a dogleg-shaped track on
the LRU rack. After engaging the dogleg, the handle can be pushed
down and locked. This action seats the LRU against the rear plate and
connectors. A single Phillips screw is used to fasten the lever to the LRU
body. Gently insert the GIA 63W into its rack. The handle should engage
the dogleg track.
CAUTION
Some pressure is required to seat the LRU and lock the handle. The unit
should be gently worked into position using the lever. Do not use
excessive force inserting the LRU. If the LRU binds or is caught, stop
and remove it. Check and make sure the rear plate and connectors are
floating freely in the LRU rack before attempting to re-install.
2. Push down on the GIA 63W handle to lock the unit into the rack.
3. Lock the handle to the GIA 63W body using the Phillips screw.
4. Reinstall the MFD.
5. No software or configuration loading is required if the removed GIA is reinstalled in it’s
original position (GIA1 and GIA2 in their original racks). This does not include units that
were returned for repair as their software and configuration files are deleted during the
repair testing process. Proceed to Section 8.2.