• When connecting a NMEA 0183 device with only one
transmitting (Tx) wire or with only one receiving (Rx) wire,
the NMEA 2000 bus and the NMEA 0183 device must be
connected to a common ground.
Basic NMEA 0183 Connections
These diagrams illustrate basic NMEA 0183 wiring used to connect your device to NMEA 0183-compliant devices. For more
information on the NMEA 0183 capabilities of the device, see Advanced NMEA 0183 Connections.
Standard NMEA 0183-Compliant Device
Item Description
À
12 Vdc power source
Á
Power cable
Â
NMEA 0183-compliant device
Ã
NMEA 0183 cable
Item Garmin Wire Function Garmin Wire Color NMEA 0183 Device Wire Function
Ê
Power Red Power
Ë
Power ground Black Power ground
Ì
Data ground Black Data ground
Í
Receive A (+) White Transmit A (+)
Î
Receive B (-) Orange/white Transmit B (-)
Ï
Transmit A (+) Gray Receive A (+)
Ð
Transmit B (-) Pink Receive B (-)
Single-Ended NMEA 0183-Compliant Device
Item Description
À
12 Vdc power source
Á
Power cable
Â
NMEA 0183-compliant device
Ã
NMEA 0183 cable
Item Garmin Wire Function Garmin Wire Color NMEA 0183 Device Wire Function
Ê
Power Red Power
Ë
Power ground Black Power ground
7