Garmin G1000 Cockpit Reference Guide for the Socata TBM 700
190-01247-00 Rev. A 7
Engine & Airframe Systems
Flight
Instruments EAS
Nav/Com/
XPDR/Audio AFCS GPS Nav
Flight
Planning Procedures
Hazard
Avoidance
Additional
Features
Abnormal
Operation
Annun/
Alerts Appendix Index
1
Standby Generator
2
Main Generator
3
Ground Power Unit Door
4
Battery
5
Amperage
6
Battery Bus
7
Essential Bus
8
Battery Bus Voltage
9
Essential Bus Voltage
10
DC Buses 1through 4
11
Main Bus
Active generator currents are displayed below the generator icons. A disconnected
generator is indicated in gray; the current is removed from the display and the switch
symbol is closed.
Connected
Disconnected
Connected Disconnected
Generator Status
GPU status information is removed from the electrical diagram when the GPU door
is closed. If the GPU door is open and selected, the GPU status is shown in green;
when the door is open, but not selected, the status is shown in gray with the switch
closed. A CAS message, ‘GPU DOOR’ is generated if the GPU door is open.
Selected Not Selected
GPU Door Open
GPU Door Closed
GPU Door Status