GIA 63W MESSAGE ADVISORIES (CONT.)
Message Comments
G/S1 SERVICE
– G/S1 needs
service. Return unit for repair.
A failure has been detected in glideslope
receiver 1 and/or receiver 2. The receiver may
still be available. The system should be serviced
when possible.
G/S2 SERVICE
– G/S2 needs
service. Return unit for repair.
GSD 41 MESSAGE ADVISORIES
Message Comments
GSD1 CONFIG
– GSD1 config error.
Config service req’d.
GSD1 and the CDU have different copies of
the GSD1 configuration.
GSD2 CONFIG
– GSD2 config error.
Config service req’d.
GSD2 and the CDU have different copies of
the GSD2 configuration.
GSD1 COOLING
– GSD1
temperature too low.
GSD1 is reporting a low temperature
condition.
GSD2 COOLING
– GSD2
temperature too low.
GSD2 is reporting a low temperature
condition.
GSD1 COOLING
– GSD1 over
temperature.
GSD1 is reporting an over-temperature
condition.
GSD2 COOLING
– GSD2 over
temperature.
GSD2 is reporting an over-temperature
condition.
GSD1 SERVICE
– GSD1 needs
service. Return unit for repair.
GSD1 is reporting an internal error condition.
The GSD may still be usable.
GSD2 SERVICE
– GSD2 needs
service. Return unit for repair.
GSD2 is reporting an internal error condition.
The GSD may still be usable.
MANIFEST
– GSD1 software
mismatch. Communication halted.
GSD1 has incorrect software installed. The
system should be serviced.
MANIFEST
– GSD2 software
mismatch. Communication halted.
GSD2 has incorrect software installed. The
system should be serviced.