Instructions for Continued Airworthiness G600, GNS 530W, GNS 430W, 190-01080-05 Rev. 2
GMA 347, GTX 330D, GMX 200, WSI AV-200 Cessna 208/208B Page 26 of 29
Appendix A. Transponder/DME Cable Connector Removal & Replacement
The BNC connectors, if damaged, can be replaced individually as necessary without requiring complete
cable assembly replacement.
A.1 Transponder Cable Connectors
Table A-1 lists required tooling to accomplish the termination.
Table A-1. Transponder Cable Tooling
Military P/N = M22520/5-35
-or-
Termination Instructions, 90° Connectors (Ref Emteq Dwg ES-105-5):
1. Disconnect faulty connector from upper transponder antenna. Cut the connector off completely
using snips or diagonal cutters. Make every attempt to limit the amount of cable which is removed
along with the connector.
NOTE:
For proper transponder diversity performance,
all four cables must be within 12 inches total length of each other.
2. Slide on heat shrink labels, black adhesive heat shrink, and crimp tube. Installer is responsible
for remaking cable labels. Use existing cable label as a reference.
3. Strip the cable insulation according to the following diagram:
NOTE:
Take care not to nick the center conductor or shield braid.
Do not remove inner foil shield from dielectric.
4. Install cable insulator onto center conductor butting it up against cable dielectric, as shown: