Instructions for Continued Airworthiness G600, GNS 530W, GNS 430W, 190-01080-05 Rev. 2
GMA 347, GTX 330D, GMX 200, WSI AV-200 Cessna 208/208B Page 29 of 29
4. Install cable insulator onto center conductor butting it up against cable dielectric, as shown:
5. Tin the center conductor, then solder the contact onto the center conductor, butting the contact up
against the cable insulator. Do not exceed specified solder temperatures in Table A-2.
6. Flair the outer shield braid by gently rotating the contact and dielectric, then finish to flare out,
taking care not disturbing the inner foil shield. Do not remove the inner foil shield from the
dielectric.
7. Insert the contact into the rear of the connector body. The inner shield goes inside of the
connector body and the braid shield goes outside, until the contact snaps into place. Slide the
crimp tube up over the braid and up against the connector body. Crimp using tooling specified in
Table 5-7.
8. Install black adhesive heat shrink into place past crimp tube and up over connector body and heat
shrink into place.
9. Reattached the connector to the DME or DME antenna, as appropriate.
10. Use the Transponder/DME ramp test equipment to do a basic functional check of the DME.
Follow the ramp test equipment and DME manufacturer’s instructions.
Comentarios a estos manuales