12.8 G1000 SYSTEM MESSAGE ADVISORIES
This section describes various G1000 system message advisories. Certain messages are issued due to an LRU or an LRU
function failure. Such messages are normally accompanied by a corresponding red ‘X’ annunciation as shown previously in
the G1000 System Annunciation section.
NOTE: This section provides information regarding G1000 message advisories that may be displayed by the
system. Knowledge of the aircraft, systems, flight conditions, and other existing operational priorities must
be considered when responding to a message. Always use sound pilot judgment. The Aircraft Flight Manual
takes precedence over any conflicting guidance found in this section.
MFD & PFD Message Advisories
Message Comments
DATA LOST
– Pilot stored data was
lost. Recheck settings.
The pilot profile data was lost. System reverts to default pilot profile and settings.
The pilot may reconfigure the MFD & PFD with preferred settings, if desired.
XTALK ERROR
– A flight display
crosstalk error has occurred.
The MFD and PFD are not communicating with each other. The G1000 system
should be serviced.
PFD1 SERVICE
– PFD1 needs service.
Return unit for repair.
The PFD and/or MFD self-test has detected a problem. The G1000 system should
be serviced.
MFD1 SERVICE
– MFD1 needs
service. Return unit for repair.
MANIFEST
– PFD1 software
mismatch, communication halted.
The PFD and/or MFD has incorrect software installed. The G1000 system should
be serviced.
MANIFEST
– MFD1 software
mismatch, communication halted.
PFD1 CONFIG
– PFD1 config error.
Config service req’d.
The PFD and/or MFD configuration settings do not match backup configuration
memory. The G1000 system should be serviced.
MFD1 CONFIG
– MFD1 config error.
Config service req’d.
SW MISMATCH
– GDU software
version mismatch. Xtalk is off.
The MFD and PFD have different software versions installed. The G1000 system
should be serviced.
PFD1 COOLING
– PFD1 has poor
cooling. Reducing power usage.
The PFD and/or MFD is overheating and is reducing power consumption by
dimming the display. If problem persists, the G1000 system should be serviced.
MFD1 COOLING
– MFD1 has poor
cooling. Reducing power usage.