Garmin G1000 Cockpit Reference Guide for the Socata TBM 850
190-00708-00 Rev. A
13-14
SECTION 13 – ANNUNCIATIONS
& ALERTS
GIA 63W Message Advisories
Message Comments
GIA1 CONFIG
– GIA1 config error.
Config service req’d.
The GIA1 and/or GIA2 configuration settings do not match backup configuration
memory. The G1000 system should be serviced.
GIA2 CONFIG
– GIA2 config error.
Config service req’d.
GIA1 CONFIG
– GIA1 audio config
error. Config service req’d.
The GIA1 and/or GIA2 have an error in the audio configuration. The G1000
system should be serviced.
GIA2 CONFIG
– GIA2 audio config
error. Config service req’d.
GIA1 COOLING
– GIA1 temperature
too low.
The GIA1 and/or GIA2 temperature is too low to operate correctly. Allow units to
warm up to operating temperature.
GIA2 COOLING
– GIA2 temperature
too low.
GIA1 COOLING
– GIA1 over
temperature.
The GIA1 and/or GIA2 temperature is too high. If problem persists, the G1000
system should be serviced.
GIA2 COOLING
– GIA2 over
temperature.
GIA1 SERVICE
– GIA1 needs service.
Return the unit for repair.
The GIA1 and/or GIA2 self-test has detected a problem in the unit. The G1000
system should be serviced.
GIA2 SERVICE
– GIA2 needs service.
Return the unit for repair.
HW MISMATCH
– GIA hardware
mismatch. GIA1 communication
halted.
A GIA mismatch has been detected, where only one is WAAS capable.
HW MISMATCH
– GIA hardware
mismatch. GIA2 communication
halted.
MANIFEST
– GIA1 software
mismatch, communication halted.
The GIA1 and/or GIA 2 has incorrect software installed. The G1000 system
should be serviced.
MANIFEST
– GIA2 software
mismatch, communication halted.