Garmin Software Version 0321.23 Manual Pagina 104

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 266
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 103
Page 4-12 G1000 System Maintenance Manual – Diamond DA40/40F
Revision G 190-00545-01
o) GSR 56 Top: __________ milli-volts
p) Iridium Antenna metal base__________ milli-volts
q) GSA 81 (Pitch) Servo Body: __________ milli-volts
r) GSA 81 (Pitch Trim) Servo Body: __________ milli-volts
s) GSA 81 (Roll) Servo Body: __________ milli-volts
Ensure that at each test point, no more than 2.5 mV (2.5 m) are present. In this case, voltage is
approximately equivalent to resistance (), given that precisely 1 amp reference current is present.
NOTE
If 1 amp reference current cannot be maintained, note the difference between the
attainable current and 1 amp reference current. Calculate the percentage difference and
apply this to the voltage reading to obtain the equivalent resistance. Example: If the
measured current is 1.2 amps, (20% high from the target 1 amp current), then the
allowable voltage measurement would be 20% high, 2.5 mV would now be 3.0 mV.
Vista de pagina 103
1 2 ... 99 100 101 102 103 104 105 106 107 108 109 ... 265 266

Comentarios a estos manuales

Sin comentarios