G1000 System Maintenance Manual – Diamond DA40/40F Page 7-37
190-00545-01 Revision G
7.8.2 GDL 69 Testing
On the PFD, open the ALERT window and verify there are no GDL 69 MANIFEST or configuration
error messages.
Go to the MFD AUX – XM RADIO page and verify that the GDL 69 is reporting its Radio ID number
and receiving the XM PREVIEW channel. Refer to the Cockpit Reference Guide for details on XM
Radio weather and music operation.
If the GDL 69 is replaced, the owner must update their subscription information with XM by providing
them with the new GDL 69’s Radio ID number(s). See the XM Activation Instructions listed in Table
1-2.
7.9 GDL 59 Datalink
Original GDL 59 is Reinstalled
No software or configuration loading is required if the removed GDL 59 is re-installed. This does not
include units that were returned for repair as their software and configuration files are deleted during the
repair testing process. Continue to Section 7.9.2 if the original unit with no repairs was reinstalled.
Continue to section 7.9.1 for repaired or exchanged units.
New, Repaired or Exchanged GDL 59 is Installed
If a new, repaired, or exchanged GDL 59 is installed, the correct software and configuration files must be
loaded to the unit. Continue to the software loading procedure. As well the GFDS subscription must be
reactivated. See Section 3.5.14.
7.9.1
GDL 59 Software and Configuration File Loading
If a new, repaired or exchanged GDL 59 is installed the correct software and configuration files must be
loaded. Determine if a GSR 56 is also installed in the aircraft to select the proper option file on the
G1000 system software loader card. Follow the procedure below to load the files.
1. Remove the bottom SD cards from the displays. Note which one was removed from the MFD so
it may be identified later for reinsertion in the MFD when software and configuration loading are
complete. It might contain a FliteChart® or ChartView database which is only used in the MFD
2. Insert the correct G1000 software loader card that matches the existing G1000 system software
version in the PFD top card slot.
3. Start the displays in configuration mode.
4. On the PFD, go to the System Upload Page using the small FMS knob.
5. Push the FMS knob to activate the cursor, then rotate the small FMS knob to display a drop-down
menu in the AIRFRAME field. Turn the small FMS knob to highlight OPTIONS in the menu
and press the ENT key.
6. Once an airframe type is selected the cursor moves to the FILE field. Rotate the small FMS knob
to activate the drop-down menu. Move the cursor to highlight the ‘DA 40 Option -
GDL59/GSR56’ file and press ENT.
7. Press the CLR ALL softkey.
8. Using the FMS knob and ENT key, select the following files:
GDL59 – software and configuration files
GDL59 ROUTER – software file