Page 3-24 G1000 System Maintenance Manual – Diamond DA40/40F
Revision G 190-00545-01
3.5.1 System Power Up
Apply power to the G1000 by doing the following:
1. Ensure there are no database cards inserted in the MFD and PFD lower card slots. If there are,
remove them until instructed to install them.
2. Turn on the ground power unit, if used.
3. Turn on the BAT side master switch.
4. Turn on the AVIONICS MASTER switch. At this moment, all G1000 equipment should be
receiving power.
3.5.2 MFD & PFD Boot Block Software Check
1. Pull the MFD and PFD circuit breakers.
2. While holding the ENT key on the MFD, restore power by closing the MFD circuit breaker.
3. When the words appear in the upper left corner of the MFD,
release the ENT key.
4. Repeat Steps 2 and 3 for the PFD.
5. At this point, the MFD and PFD should be operating in configuration mode, displaying the
System Status page.
6. Activate the cursor on both displays and scroll through the list of LRUs. Highlight ‘PFD1’ on the
PFD, and ‘MFD1’ on the MFD.
7. Check the currently reported GDU boot block software version, indicated by ‘BB Version’ on
each display.
IMPORTANT!
If the GDU boot block software is less than 2.03, the boot block must be updated prior to
loading GDU 8.20 software (System Software 0321.17 or later). Continue to the next
section, Updating GDU Boot Block.
If the reported version is already 2.03, boot block is correct and does not require
updating. If GDU 9.01 software is being loaded (System Software 0321.18 or later), the
boot block will update automatically; the technician may skip to the GDU software
loading section.
3.5.3 Updating GDU Boot Block
1. Obtain the GDU boot block update software. Refer to the appropriate General Arrangement
drawing (see Table 1-2) for the boot block software P/N.
NOTE
The GDU boot block update may be obtained by downloading the electronic file from
Garmin (see GA dwg for 006- P/N, accessible via the dealer web site). This electronic
download may be used to build an SD card to update the GDU boot block. In addition,
the technician may obtain a pre-manufactured update card from Garmin, via the listed
010- card part number in the General Arrangement drawings.
2. Pull the MFD and PFD circuit breakers.
3. Insert the boot block update card into the MFD.
4. While holding the ENT key on the MFD, restore power by closing the MFD circuit breaker.