Page 6-6 G1000 System Maintenance Manual – Diamond DA40/40F
Revision G 190-00545-01
6.5.1 GDC 74A Air Data Computer
Removal:
1. Gain access to the space behind the instrument panel by removing the panel cover.
2. Disconnect the pitot/static plumbing from the rear of the unit. Disconnect the single
connector.
3. Loosen each thumbscrew on the hold-down clamp and remove the clamp.
4. Carefully remove the unit from its mount.
Replacement:
1. Place the unit in the mounting tray.
2. Position the locking clamp and fasten using the thumbscrews.
3. Connect the pitot/static plumbing.
4. Inspect the connector and pins for damage. Repair any damage. Connect the connector to
the unit.
5. Configure and test the GDC 74A according to Section 7.6.
6.6 GTP 59 OAT Probe
Removal:
1. Remove the co-pilot seat per the DA 40 Aircraft Maintenance Manual.
2. Use a deep-socket to hold the probe in place on the outside of the aircraft. Inside the cockpit,
loosen the GTP 59 mounting nut and remove the GTP 59.
Replacement:
1. Replacement is the reverse of removal.
2. No configuration is required for the GTP 59. Test according to Section 7.6.5.
6.7 GRS 77 AHRS
Removal:
1. Remove baggage compartment floor, then remove the baggage compartment.
2. Disconnect the AHRS connector.
3. Remove the four Phillips thumbscrews with a screwdriver and set them aside.
4. Gently lift the GRS 77 from the mounting plate (If the mounting plate is removed, the GRS 77
must
be re-calibrated. See Section 7.7).
Replacement:
1. Place the GRS 77 on the mounting plate, ensuring the orientation is correct.
2. Fasten the unit to the plate using the Phillips thumbscrews.
3. Visually inspect the connectors to ensure there are no bent or damaged pins. Repair any
damage. Connect the connector to the GRS 77.
4. Calibrate, and test the GRS 77 according to Section 7.7.