Page 4-18 G1000 System Maintenance Manual – Diamond DA40/40F
Revision G 190-00545-01
Figure 4-5 Fuel Calibration Page (Empty Calibration)
6. On the MFD, verify the fuel quantity indicator correctly point to ‘0’ for the affected tank.
7. Before proceeding verify that the cursor is deactivated on the Fuel Tank Calibration page. If
necessary depress the FMS knob to deactivate the cursor.
8. Using the FMS knobs, go to the SYSTEM – SYSTEM UPLOAD page on the PFD, as shown:
Figure 4-6 System Upload Page
9. Press the UPDT CFG softkey, located in the lower right corner of the System Upload page.
10. A prompt will appear: “Update Config Module?”
11. Select YES and press the ENT key on the PFD.
12. The system will update the configuration module located in the PFD connector and prompt the
technician when successfully complete. Press the ENT key to acknowledge the prompt.
13. Go to the CAL Page Group on the PFD and select the FUEL TANK CALIBRATION page.
14. Repeat these steps for the opposite tank, if both sides require recalibration.