Garmin Software Version 0321.23 Manual Pagina 106

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 266
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 105
Page 4-14 G1000 System Maintenance Manual – Diamond DA40/40F
Revision G 190-00545-01
Figure 4-2 Fuel Calibration Page (Calibration Table)
4.6.1 Fuel Tank Calibration File Loading
Reference Section 3.4 to determine the appropriate software version for the current aircraft configuration.
Once the determination has been made use the appropriate system software loader card to load the Fuel
Calibration files.
1. If not already in configuration mode, restart the PFD in configuration mode by pulling, then
resetting, the PFD circuit breaker while holding the ENT key.
2. On the PFD, at the System Upload page, activate the cursor and use the small FMS knob to
highlight the CALIBRATION option in the GROUP field.
3. Press the ENT key.
4. Once the CALIBRATION file is selected the cursor moves to the ITEM window. Rotate the
small FMS knob to active the drop-down menu. Move the cursor to highlight the appropriate fuel
tank calibration (standard or extended range) and press ENT.
IMPORTANT!
It is at this step where the choice is given to load standard range or extended range fuel
tank default calibration parameters. Be sure to select the correct option.
5. The CAL file is shown in the PRODUCT window. Verify it is ‘checked’ then press the LOAD
softkey.
Vista de pagina 105
1 2 ... 101 102 103 104 105 106 107 108 109 110 111 ... 265 266

Comentarios a estos manuales

Sin comentarios