Page 4-20 G1000 System Maintenance Manual – Diamond DA40/40F
Revision G 190-00545-01
10. Using the FMS knobs, go to the SYSTEM – SYSTEM UPLOAD page on the PFD, as shown:
Figure 4-8 System Upload Page
11. Press the UPDT CFG softkey, located in the lower right corner of the System Upload page.
12. A prompt will appear: “Update Config Module?”
13. Select YES and press the ENT key on the PFD.
14. The system will update the configuration module located in the PFD connector and prompt the
technician when successfully complete. Press the ENT key to acknowledge the prompt.
15. Go to the CAL Page Group on the PFD and select the FUEL TANK CALIBRATION page.
16. Repeat these steps for the opposite tank, if both sides require recalibration.
17. In the CALIBRATION TABLE, verify that each tank side has a 0.00 GL point, a 5.00 GL point,
and a full point (16.66 GL for standard range tanks, 20.95 GL for the LEFT long range tank and
21.17 GL for the RIGHT long range tank).
Figure 4-9 Fuel Calibration Page (Calibration Complete)