Page 7-22 G1000 System Maintenance Manual – Diamond DA40/40F
Revision G 190-00545-01
12. After the software and configuration files are loaded, turn off the system and remove the G1000
system software loader card. Reinsert the supplemental database cards in the bottom slot of each
display. Be sure to insert the card removed from the MFD back into the MFD.
13. Continue to the GDC 74A Testing section.
7.6.2 GDC 74A Testing
Apply power to the G1000 and allow system to initialize.
IMPORTANT!
Allow unit to warm up for 15 minutes before performing the following tests.
On the PFD, open the ALERT window and verify there are no GDC MANIFEST or configuration error
messages.
Verification of the altimeter and airspeed must be performed using a pitot/static ramp tester. The static
port and altimeter must be verified in accordance with Title 14 of the Code of Federal Regulations (CFR)
§ 91.411 and Part 43 Appendix E, every 24 calendar months.
For system software 0321.17 or later, the G1000 pitot/static system may be tested in normal display
mode.
To properly conduct these tests on G1000 systems equipped with System Software Version 0369.13 or
earlier, perform the following procedure:
To prepare the G1000 System for Part 43 Appendix E testing (0369.13 or earlier only):
1. Remove power to the PFD by pulling the circuit breaker labeled PFD.
2. Press and hold the ENT key on the PFD while applying power using the PFD circuit breaker.
3. Release the ENT key after ‘INITIALIZING SYSTEM’ appears in the upper left corner of the
PFD.
4. Rotate the FMS knob to until the display shows the GRS page group. Within the Air Data 1 sub
window is the field “B ALT” which is Barometric Altitude. B ALT is equivalent to the altitude
that will be displayed to the pilot on the altitude display when the PFD is in normal mode. B ALT
will be used for all CFR Part 43 Appendix E tests for G1000 altitude.
5. Push the red “display backup” button on the audio panel. This will activate Reversionary Mode
for the MFD. Baro settings can then be read from the MFD for the CFR Part 43 Appendix E tests.
6. After completing the tests specified by § 91.411 and Part 43 Appendix E, return the MFD to
normal mode by pushing the red “display backup” button. Return the PFD to normal mode by
pulling the PFD circuit breaker and then resetting.
NOTE
The following tests are above and beyond the requirements set forth in Appendix E.