Page 5-48 G1000 System Maintenance Manual – Diamond DA40/40F
Revision G 190-00545-01
Table 5-30. Miscellaneous Alerts (Cont)
Failure Message Cause Solution
MFD1 SERVICE – needs service.
Return unit for repair.
The G1000 has determined MFD1
needs service.
Ensure the display connector is fully
seated and locked.
If the unit was started in a very dark
environment the photocells may not
have enough light to initially raise the
CCFT level.
Go to the GDU STATUS page in
configuration mode, ensure CCFT
CRNT 1 & 2 levels are above 50.
9 If the CCFT levels are not
above 50, apply light to the
photocell and observe if the
CCFT level rises.
9 If the CCFT level rises,
disregard the message.
9 If the CCFT level does not rise,
replace the display.
Replace the display.
PFD1 SERVICE – needs service.
Return unit for repair.
The G1000 has determined the
PFD needs service.
9
PFD1 VOLTAGE – PFD1 has low
voltage. Reducing power usage.
The PFD supply voltage is low.
Verify aircraft power is at proper voltage
level and that the alternator or battery
have not failed. Refer to the Diamond
AMM for electrical troubleshooting
information.
Ensure the GDU rear connector is
properly connected.
Check wiring.
MFD1 VOLTAGE – MDF1 has low
voltage. Reducing power usage.
The MFD supply voltage is low.
Vista de pagina 179