G1000 System Maintenance Manual – Diamond DA40/40F Page 5-47
190-00545-01 Revision G
5.8.6 Miscellaneous Alerts
Table 5-30. Miscellaneous Alerts
Failure Message Cause Solution
XTALK ERROR – A flight display
cross talk error has occurred.
A communication error has
occurred between the MFD and
PFD.
Ensure a database error has not
occurred
9 If a database error has
occurred, correct error before
proceeding.
Verify that both PFD and MFD are
receiving power.
In Configuration Mode, check the
System Configuration page:
9 Ensure that MFD1 and PFD1
are green.
9 If configuration is not correct,
reconfigure the PFD and MFD
per Section 3.5.
Check Ethernet interconnect.
Replace PFD with a known good unit to
verify location of problem:
9 If problem persists, replace
MFD.
9 If problem does not persist,
replace PFD.
DATA LOST – Pilot stored data
lost. Recheck settings.
Pilot stored data has been lost.
If the CLR key was held during a power
cycle, disregard message.
Cycle power to PFD1:
9 Ensure CLR key is not stuck
on the GDU TEST page.
9 If problem persist, replace
PFD1.